Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.655
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38703331

RESUMO

BACKGROUND: Residual non-pulmonary vein (PV) foci are significantly associated with atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). However, we previously reported among patients with non-PV foci induced only once, none experienced AF recurrence. Thus, we aimed to investigate the correlation between the residual induction number of non-PV foci and ablation outcome in paroxysmal AF patients. METHODS AND RESULTS: We investigated 55 paroxysmal AF patients with residual non-PV foci after PVI and ablation of non-PV-foci. Study patients were classified into the residual one-time induction of non-PV foci (residual OTI-nPVF) group (n = 23) and residual repeatedly induced non-PV foci (residual RI-nPVF) group (n = 32). Furthermore, the residual RI-nPVF group was divided into the low inducibility group (n = 10) and high inducibility group (n = 22) according to the presence or absence of non-PV foci provoked by two sets of drug induction tests (non-PV foci inducibility). In addition, the latter was divided into the ablation group (n = 14) or observation group (n = 8). The 2-year AF recurrence-free rate in the residual RI-nPVF group was significantly lower compared to the residual OTI-nPVF group (53% vs. 90%, p = 0.018). There was no significant difference of the 2-year AF recurrence-free rates in the inducibility of non-PV foci (p = 0.913) and the presence or absence of ablation (p = 0.812) in the residual RI-nPVF group. CONCLUSIONS: Among paroxysmal AF patients, the presence of residual RI-nPVF was associated with higher AF recurrence compared to residual OTI-nPVF. Furthermore, within residual RI-nPVF subgroup, non-PV foci inducibility or ablation of some residual RI-nPVF did not affect ablation outcome.

2.
J Cardiothorac Surg ; 19(1): 169, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566062

RESUMO

BACKGROUND: Atrial tachycardia (AT) originating from the left atrial appendage (LAA) is uncommon and the most difficult arrhythmia to eliminate. Therefore, we present the case of a 5-year-old girl with tachycardia-induced cardiomyopathy (TIC) caused by AT originating from the LAA and successfully treated with RFCA associated to left atrial appendectomy. With resolution of AT, we observed a progressive improvement of LV function. The effectiveness and safety of this combination therapy were evaluated over a one-month follow-up period. CASE PRESENTATION: A 5 -year-old female was evaluated for three days of incessant cough and a syncopal episode. Surface echocardiography and 24-hour monitoring showed that the infant had persistent atrial tachycardia. Echocardiography revealed an enlarged tele diastolic diameter (46.1 mm) and malfunctioning (EF 28.53%) left ventricle. The location of the lesion at the apex of the LAA was further confirmed by electrophysiological study and RFCA. After RFCA, the infant's ECG monitor showed that sinus rhythm was maintained for up to 22 h. Subsequently, atrial tachycardia recurred and sinus rhythm disappeared. Finally, atrial appendectomy was performed and sinus rhythm returned to normal. CONCLUSIONS: The heart function of the infant improved and sinus rhythm was maintained, further demonstrating the safety and effectiveness of combined treatment with RFCA and atrial appendectomy after electrophysiological localization of AT from LAA to TIC.


Assuntos
Cardiomiopatias , Ablação por Cateter , Pré-Escolar , Feminino , Humanos , Apendicectomia , Cardiomiopatias/cirurgia , Átrios do Coração/cirurgia , Taquicardia/cirurgia
4.
J Cardiol ; 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38565394

RESUMO

Cardiac amyloidosis (CA) is related to the aggregation of insoluble fibrous deposits of misfolded proteins within the myocardium. Transthyretin amyloidosis (ATTR) and immunoglobulin light-chain amyloidosis are the main forms of CA. Atrial fibrillation (AF) is a common arrhythmia in CA patients, especially in those with ATTR amyloidosis. Increased atrial preload and afterload, atrial enlargement, enhanced atrial wall stress, and autonomic dysfunction are the main mechanisms of AF in CA patients. CA is associated with the formation of endocardial thrombi and systemic embolism. The promoters of thrombogenesis include endomyocardial damage, blood stasis, and hypercoagulability. The prevalence of thrombi in patients with AF remains elevated despite long-term anticoagulation. Consequently, transesophageal ultrasound examinations before cardioversion should be performed to exclude endocardiac thrombi despite anticoagulation. Furthermore, the CHA2DS2-VASc score should not be used to assess the thromboembolic risk in CA patients with AF. Rate control is challenging in patients with CA, while rhythm control is the preferred treatment option, especially in the early stages of the disease process. Although catheter ablation is an effective treatment option, more data are needed to explore the role of the procedure in CA patients.

5.
Eur Heart J Case Rep ; 8(4): ytae140, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572018

RESUMO

Background: Pulmonary vein (PV) stenosis is a rare complication after catheter ablation for atrial fibrillation (AF). While there have been reported anecdotal cases of complete PV stenosis requiring pulmonary lobectomy, only one case of pneumonectomy has been documented so far. Case summary: A 42-year-old man was referred to our Thoracic Surgery Unit for recurrent haemoptysis and exertional dyspnoea over the past 4 years and a recent finding of left PV occlusion. He suffered of relapsing AF that had almost five recurrences and that underwent a total of two percutaneous catheter ablations within a 7-year period. He also experienced a hospitalization for multifocal lobar pneumonia. Two attempts of percutaneous transluminal angioplasty (PTA) were unsuccessful. Due to the severity and the duration of PV occlusion, the previous PTA failure, the patient's age, and his symptoms, a left pneumonectomy was performed. During the postoperative period, the patient experienced only mild anaemia effectively managed with blood transfusions. Five months after surgery, he has no recurrence of symptoms. Discussion: When the PV stenosis is complete, PTA may face high failure and recurrence rates. In this setting, anatomical pulmonary resections may represent a valid option to allow symptom relief and resolution.

6.
Cardiol Young ; : 1-6, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38572563

RESUMO

AIM: Malignant vasovagal syncope in children seriously affects their physical and mental health. Our study aimed to explore the efficacy of catheter ablation in ganglionated plexus with malignant vasovagal syncope children. CONCLUSION: Catheter ablation of ganglionated plexus was safe and effective in children with malignant vasovagal syncope and can be used as a treatment option for these children. METHODS: A total of 20 children diagnosed with malignant vasovagal syncope were enrolled in Beijing Children's Hospital, affiliated with Capital Medical University. All underwent catheter ablation treatment of ganglionated plexus. Ganglionated plexuses of the left atrium were identified by high-frequency stimulation and/or anatomic landmarks being targeted by radiofrequency catheter ablation. The efficacy of the treatment was evaluated by comparing the remission rate of post-operative syncopal symptoms and the rate of negative head-up tilt results. Safety and adverse events were evaluated. RESULTS: After follow-up for 2.5 (0.6-5) years, the syncope symptom scores were decreased significantly compared with before treatment [3 (2-4) versus 5 (3-8) scores, P < 0.01]. Eighty-five per cent (17/20) children no longer experienced syncope, whilst 80% (16/20) children showed negative head-up tilt test after treatment. No adverse effects such as cardiac arrhythmia occurred in the children.

8.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592136

RESUMO

Background: Atrial fibrillation (AF) catheter ablation in cancer patients has been evaluated in very few studies. We aimed to investigate utilization trends and in-hospital outcomes of AF catheter ablation among cancer patients in a large US inpatient registry. Methods: Utilizing the National Inpatient Sample (NIS) database, patients who underwent AF catheter ablation between 2012 and 2019 were identified. Sociodemographic, clinical data, in-hospital procedures and outcomes were collected. Baseline characteristics and in-hospital outcomes were compared between patients with and without cancer. Results: An estimated total of 67,915 patients underwent AF catheter ablation between 2012 and 2019 in the US. Of them, 950 (1.4%) had a cancer diagnosis. Patients with a cancer diagnosis were older and had higher Charlson Comorbidity Index, CHA2DS2-VASc and ATRIA bleeding indices scores. A higher rate of total complications was observed in cancer patients (10.5% vs. 7.9, p < 0.001), driven mainly by more bleeding and infectious complications. However, no significant differences in cardiac or neurological complications as well as in-hospital mortality rates were observed and were relatively low in both groups. Conclusions: AF catheter ablation in cancer patients is associated with higher bleeding and infectious complication rates, but not with increased cardiac complications or in-hospital mortality in a US nationwide, all-comer registry.

9.
Ann Cardiothorac Surg ; 13(2): 155-164, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38590997

RESUMO

Background: CONVERGE was a prospective, multicenter, randomized controlled trial that evaluated the safety of Hybrid Atrial Fibrillation Convergent (HC) and compared its effectiveness to endocardial catheter ablation (CA) for the treatment of persistent atrial fibrillation (PersAF) and longstanding PersAF (LSPAF). In 2020, we reported that CONVERGE met its primary safety and effectiveness endpoints. The primary objective of the present study is to report CONVERGE trial results for quality of life (QOL) and Class I/III anti-arrhythmic drug (AAD) utilization following HC. Methods: Eligible patients had drug-refractory symptomatic PersAF or LSPAF and a left atrium diameter ≤6.0 cm. Enrolled patients were randomized 2:1 to receive HC or CA. Atrial Fibrillation Severity Scale (AFSS) and the 36-Item Short Form Health Survey (SF-36) were assessed at baseline and 12 months; statistical comparison was performed using paired t-tests. AAD utilization at baseline through 12 and 18 months post-procedure was evaluated; statistical comparison was performed using McNemar's tests. Results: A total of 153 patients were treated with either HC (n=102) or CA (n=51). Of the 102 HC patients, 38 had LSPAF. AFSS and SF-36 Mental and Physical Component scores were significantly improved at 12 months versus baseline with HC overall and for the subset of LSPAF patients treated with either HC or CA. The proportion of HC patients (n=102) who used Class I /III AADs at 12 and 18 months was significantly less (33.3% and 36.3%, respectively) than baseline (84.3%; P<0.001). In LSPAF patients who underwent HC (n=38), AADs use was 29.0% through 18 months follow-up versus 71.1% at baseline (P<0.001). Conclusions: HC reduced AF symptoms, significantly improved QOL, and reduced AAD use in patients with PersAF and LSPAF. ClinicalTrialsgov Identifier: NCT01984346.

10.
J Cardiothorac Surg ; 19(1): 238, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632637

RESUMO

BACKGROUND: There is insufficient information regarding the bleeding sites and surgical strategies of cardiac tamponade during catheter ablation for atrial fibrillation (AF). CASE PRESENTATION: Of the five patients with cardiac tamponade, three required surgical intervention and two required pericardiocentesis. In the first case of three cardiac tamponades requiring surgical intervention, considering that the peripheral route was used, the catecholamines did not reach the heart, and due to unstable vital signs, venoarterial extracorporeal membrane oxygenation (VA-ECMO) was inserted. No bleeding point was identified, but a thrombus had spread around the left atrium (LA) with diverticulum. Hemostasis was achieved with adhesives placed around the LA under on-pump beating. In the second case, pericardiocentesis was performed, but the patient showed heavy bleeding and unstable vital signs. Thus, VA-ECMO was inserted. Heavy bleeding was expected, and safety was enhanced by attaching a reservoir to the VA-ECMO. The bleeding point was found between the left upper pulmonary artery and LA under cardiac arrest to obtain a good surgical view for suturing repair. In the third case, the LA diverticulum was damaged. Pericardiocentesis resulted in stable vitals, but sustained bleeding was present. A bleeding point was found at the LA diverticulum, and suture repair under on-pump beating was performed. CONCLUSIONS: When cardiac tamponade occured in any patient with LA diverticulum, treatment could not be completed with pericardiocentesis alone, and thoracotomy was likely to be necessary. If the bleeding point could be confirmed, suturing technique is a more reliable surgical strategy than adhesive alone that leads to pseudoaneurysm. If the bleeding point is unclear, it is important to confirm the occurrence of LA diverticulum using a preoperative CT, and if confirmed, cover it with adhesive due to a high possibility of diverticulum bleeding. The necessity of CPB should be determined based on whether these operations can be completed while maintaining vital stability.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Divertículo , Humanos , Fibrilação Atrial/cirurgia , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/métodos , Divertículo/cirurgia , Átrios do Coração/cirurgia , Hemorragia/etiologia , Toracotomia , Resultado do Tratamento
11.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38588039

RESUMO

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Assuntos
Fibrilação Atrial , Criocirurgia , Traumatismos dos Nervos Periféricos , Nervo Frênico , Veias Pulmonares , Sistema de Registros , Humanos , Nervo Frênico/lesões , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Veias Pulmonares/cirurgia , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Estudos Prospectivos , Incidência , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Pessoa de Meia-Idade , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
12.
Heart Rhythm ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38615868

RESUMO

BACKGROUND: Idiopathic atypical (non-cavotricuspid isthmus-dependent) atrial flutter (IAAFL) may be seen in patients without structural heart disease and without previous cardiac surgery or ablation. OBJECTIVE: This study sought to determine the patient characteristics, electrophysiologic and electroanatomic properties, and clinical outcomes after ablation in patients with IAAFL. METHODS: We retrospectively compared IAAFL patients with cavotricuspid isthmus-dependent AFL (C-AFL) patients undergoing catheter ablation. The primary outcome was a composite of death from cardiovascular causes, ischemic stroke, and hospitalization for worsening of heart failure. RESULTS: Of 180 patients who underwent catheter ablation for AFL, 89 were included in this study (22 IAAFL and 67 C-AFL). Electrophysiologic study showed significantly longer intra-atrial conduction time and lower atrial voltage during sinus rhythm in the IAAFL group compared with the C-AFL group. The atrial scar was observed in all 22 IAAFL patients, with the most common sites being the posterior or lateral wall of the right atrium in 10 (45.5%) and the anterior wall of the left atrium in 8 (36.4%). During 3.5 ± 2.8 years of follow-up, the composite primary end point occurred significantly more frequently in the IAAFL group (hazard ratio [HR], 3.45; 95% confidence interval [CI], 1.20-9.89; P = .015). In multivariable analysis, brain natriuretic peptide levels (HR, 1.01; 95% CI, 1.00-1.01, per 1 pg/mL; P = .01) and IAAFL (HR, 4.14; 95% CI, 1.21-14.07; P = .02) were independently associated with the primary outcome. CONCLUSION: IAAFL in patients had distinct electrophysiologic features suggestive of atrial cardiomyopathy. These patients are at risk for development of cardiovascular adverse events after ablation.

14.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471835

RESUMO

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Angiopoietina-2 , Interleucina-6 , Modelos Estatísticos , Volume Sistólico , Remodelação Ventricular , Fatores de Risco , Prognóstico , Recidiva , Função Ventricular Esquerda , Biomarcadores , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501333

RESUMO

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Reoperação , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/cirurgia , Cicatriz/etiologia , Fatores de Tempo , Potenciais de Ação , Agulhas , Frequência Cardíaca , Fatores de Risco , Resultado do Tratamento
16.
J Am Heart Assoc ; 13(6): e033146, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471838

RESUMO

BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
18.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38450791

RESUMO

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Fluoroscopia , Pontuação de Propensão
19.
Quant Imaging Med Surg ; 14(3): 2213-2224, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38545056

RESUMO

Background: There is an increasing evidence that pulmonary vein (PV) enlargement is associated with atrial fibrillation (AF); however, the predictive value of PV enlargement in AF recurrence remains unclear. This study sought to evaluate whether PV volume quantification derived from cardiac computed tomographic angiography (CCTA) could serve as a predictive indicator of the success of the catheter ablation (CA) procedure. Methods: The data of 160 patients diagnosed with AF who underwent both CCTA and CA treatments from January to June 2020 were retrospectively examined; the CCTA was conducted before the CA surgery. The study focused on documenting the PV structure, and the volume of the PV and left atrium (LA). The clinical, CCTA, and echocardiographic predictors of the recurrence and no-recurrence groups were compared. A multivariable logistic regression analysis was performed to adjust for confounders. Receiver operating characteristic (ROC) curves were analyzed to assess the predictive performance of the predictors of AF recurrence. Results: Of the 160 patients [55.6% male, 62.00 (55.25-68.00) years, 23.1% with persistent AF], 45 (28.1%) experienced AF recurrence within a one-year period. Notably, patients with AF recurrence had elevated CHADS2 scores (P=0.020) and increased LA and PV volumes (P<0.05). Patients with persistent AF (n=37) had significantly larger LA volume indexes (P<0.001) than those with paroxysmal AF, but there was no difference between the two groups in terms of the PV maximum volume index (P=0.200). Moreover, the PV maximum volume index [odds ratio (OR): 1.244, 95% confidence interval (CI): 1.008-1.536, P=0.042] and the LA minimum volume index (OR: 1.026, 95% CI: 1.001-1.052, P=0.038) were found to be significant predictors of AF recurrence. The ROC curves revealed that the PV maximum volume index threshold for predicting AF recurrence was 7.13 mL/m2, with a sensitivity of 84.4% and a specificity of 34.8% [area under the curve (AUC): 0.635, 95% CI: 0.540-0.730, P=0.008], and the LA minimum volume index threshold for predicting AF recurrence was 46.16 mL/m2, with a sensitivity of 88.9% and a specificity of 31.3% (AUC: 0.629, 95% CI: 0.534-0.723, P=0.012). A sub-analysis of patients with a lower left atrial dimension (LAD ≤38 mm in females, LAD ≤40 mm in males, n=120) demonstrated that the PV maximum volume index was a noteworthy indicator of AF recurrence (OR: 1.443: 95% CI: 1.145-1.820, P=0.002). Conversely, no significant correlation between AF recurrence and the LA volume index was found. The AUC value for the PV maximum volume index predictive of recurrent AF was 0.680 (95% CI: 0.577-0.781, P=0.003), with a sensitivity of 75.8%, specificity of 54%, and the cut-off value of the maximum AUC was 7.89 mL/m2. Conclusions: PV volume, derived from CCTA, may help to predict the recurrence of AF after CA, and is superior to the LA size in patients with less pronounced LA enlargement.

20.
Front Cardiovasc Med ; 11: 1253554, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38374993

RESUMO

Purpose: This study aimed to investigate the effect of Marshall ethanol infusion (VOM-Et) in the vein on mitral isthmus (MI) ablation. Methods: Patients with persistent atrial fibrillation (AF) were grouped into vein of VOM-Et combined with radiofrequency (RF) ablation (VOM-Et-RF) and RF groups. The primary outcome was MI block immediate block rate after surgery. Stratified analysis was also performed for factors affecting the outcome measures. Results: A total of 118 consecutive patients underwent AF ablation at Taizhou Hospital of Zhejiang Province from January 2018 to December 2021. Successful bidirectional perimitral block was achieved in 96% of patients in VOM-Et-RF (69 of 72) and in 76% of patients in the RF group (35 of 46) (P < 0.01). In the subgroup analysis, male sex, elder than 60 years, Left atrial diameter <55 mm, and AF duration <3 years were associated with the benefits of VOM-Et in AF Patients. Conclusion: The vein of Marshall ethanol infusion for catheter ablation can improve the MI block rate. Male sex, elder age, smaller Left atrial diameter and shorter AF duration may have significant benefits for VOM-Et.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA